Facility inspection checklist

A recurring walk-through checklist for facility managers, maintenance staff and safety leads in offices, schools, warehouses and public buildings. It follows a building lap in order: grounds, envelope, roof access, interior, MEP, life safety, accessibility and housekeeping. For capital planning, use a facility condition assessment instead.

Add your email to download. It goes to the Inspectial team, not a mailing list (privacy).

First page of the free Facility inspection checklist PDF

What is a facility inspection checklist?

A facility inspection checklist is a form for a routine walk-through of a building and its grounds. The inspector checks parking and walkways, the exterior envelope, roof access, interior finishes, mechanical, electrical and plumbing equipment, exits and fire safety, accessibility and housekeeping, records hazards and maintenance needs, and assigns work orders so small problems are fixed before they grow.

When to inspect

No single rule sets a building walk-through interval, but several OSHA and NFPA items have their own: OSHA 1910.22 requires walking-working surfaces to be inspected regularly, OSHA 1910.157 and NFPA 10 call for a monthly visual check of portable fire extinguishers, and NFPA 101 calls for monthly and annual emergency lighting tests. Most owners run the full walk-through monthly or quarterly and after storms.

The checklist

Every row is one observable check. Mark one answer per row and write what you saw or measured; the PDF adds a findings table and sign-off.

Header

Facility name
Building or area
Address
Building use
Floors and approximate area
Areas covered this visit
Previous inspection date
Open work orders from last visit
Inspector
Date and time
Weather

Grounds, parking and walkways

CheckOKIssueN/ANotes / value
Parking lot surface free of potholes, heaving or trip hazards
Walkways and curbs free of cracks, gaps or heaving over about 1/4 in
Exterior lighting working at entrances, walkways and parking
Signage, striping and fire lanes visible and unobstructed
Drainage working: no ponding against the building, downspouts discharge away
Landscaping trimmed back from the building, lights and signs
Fences, gates and bollards intact
Dumpster area clean, lids closed, enclosure intact

Building envelope

Walk the full perimeter. Look up at the walls and down at the foundation.

CheckOKIssueN/ANotes / value
Exterior walls free of cracks, loose cladding or missing mortar
No staining, efflorescence or water marks below windows and roof edges
Sealant at windows, doors and joints intact, not cracked or missing
Windows unbroken, frames intact, operable windows close and latch
Exterior doors close, latch and lock; weatherstripping intact
Foundation free of cracks, settlement or exposed soil gaps
No pest entry points (gaps, holes, damaged vents or screens)

Roof access and roof

Look from the hatch or a safe vantage point unless you are trained and protected for roof work.

CheckOKIssueN/ANotes / value
Roof hatch or access door secure, ladder and guardrails intact
Roof surface free of ponding, blisters, tears or loose membrane
Drains, scuppers and gutters clear of debris
Flashing at parapets, curbs and penetrations intact
Rooftop equipment secured, panels in place, no visible leaks

Interior spaces

CheckOKIssueN/ANotes / value
Ceilings free of stains, sagging or missing tiles (sign of roof or pipe leaks)
Walls free of holes, cracks or water damage
Floors free of trip hazards, loose tiles, torn carpet or wet areas
Stairs and handrails secure, treads and nosings intact
Interior doors and hardware working, fire doors close and latch on their own
No visible mold or musty odor
Restrooms working: fixtures, flush valves, supplies, ventilation
Interior lighting working, no failed or flickering fixtures

Mechanical, electrical and plumbing

Visual check only. Leave testing and servicing to qualified technicians.

CheckOKIssueN/ANotes / value
Mechanical rooms locked, clean and not used for storage
HVAC units running without unusual noise, vibration or odor
Filters changed on schedule (check the tag date)
Thermostats and temperatures in the normal range for occupied areas
Electrical panels closed, labeled, and clear in front (OSHA working space, often 3 ft)
No exposed wiring, missing cover plates or overloaded power strips
No extension cords used as permanent wiring
No leaks at pipes, valves, water heaters or under sinks
Floor drains and sump pumps working, drain covers in place
Generator and transfer switch area clear, maintenance tag current

Life safety and fire protection

CheckOKIssueN/ANotes / value
Exit routes clear and unobstructed to the outside (OSHA 1910.37)
Exit signs lit and visible from the path of travel
Emergency lights working (press-to-test) and test log current
Exit doors open from the inside without a key or special knowledge
Fire extinguishers in place, visible, charged and monthly tag current
Sprinkler heads unobstructed, at least 18 in clear below, not painted or damaged
Fire alarm pull stations and devices unobstructed and undamaged
Fire riser and sprinkler valve room accessible, valves open and secured
Evacuation maps posted and current
First aid kits and AED in place and stocked, AED status light OK

Accessibility

A routine check of existing features, not a full ADA compliance survey.

CheckOKIssueN/ANotes / value
Accessible parking spaces and signs present, access aisles striped and clear
Accessible route from parking to entrance free of barriers
Ramps and handrails intact, no cracks or loose rails
Accessible entrance doors open with low force, automatic openers working
Elevators working, inspection certificate current and posted
Accessible restroom clear of stored items, grab bars secure

Housekeeping and storage

CheckOKIssueN/ANotes / value
Storage kept off the floor in exit routes, stairwells and corridors
Storage kept away from electrical panels, heaters and fire equipment
Chemicals labeled, stored in proper cabinets, safety data sheets available
Waste and recycling bins emptied, no overflow
Janitorial closets clean, no wet mops or rags left out
No signs of pests (droppings, nests, damage)

Follow-up

CheckYesNoN/ANotes / value
Immediate hazard found and area made safe or closed off
Work orders created for each issue found
Items from the last inspection closed or re-reported
Issue for a specialist (roof, HVAC, fire protection, elevator) flagged

Priority for each issue

OK
Working and in acceptable condition. No action.
Low
Cosmetic or minor wear. Fix during routine maintenance.
Medium
Affects function or will get worse. Fix within the next maintenance cycle.
High
Safety hazard, code issue or active damage such as a leak. Fix now or make safe.

Photos to take

  1. Each building elevation, wide
  2. Main entrance and accessible route
  3. Roof from the access point
  4. Mechanical and electrical rooms, wide
  5. Each issue found, close-up with a scale reference and a wide shot for location
  6. Fire extinguisher and emergency light tags, where dates are checked

Field tips

  • Walk the same route every time so issues are easy to compare from one inspection to the next.
  • Take a wide shot and a close-up of every issue. The wide shot tells the technician where to go.
  • Turn every issue into a work order with an owner and a due date before you leave. A checklist without follow-up is just paperwork.
  • Check ceilings in every room. Stained tiles are often the first sign of a roof or pipe leak.
  • Read the dates on extinguisher tags, elevator certificates and filter tags; an expired date is easy to spot and easy to fix.
  • Note recurring items. The same leak or broken door three times in a row belongs in the capital plan, not on the next checklist.

Questions

What is the difference between a facility inspection and a facility condition assessment?

A facility inspection is a routine walk-through, often monthly or quarterly, that finds hazards and maintenance needs and turns them into work orders. A facility condition assessment is a less frequent, deeper review that rates every building system, estimates remaining life and repair costs, and feeds a capital plan.

How often should a building be inspected?

Most owners do a full walk-through monthly or quarterly, with some items on their own schedule. OSHA and NFPA 10 call for a monthly visual check of fire extinguishers, NFPA 101 for monthly emergency light tests, and OSHA 1910.22 for regular inspection of walking-working surfaces. Inspect again after storms or any leak.

What should be on a building inspection checklist?

Grounds and parking, the exterior walls, windows and doors, roof access and drains, interior finishes, HVAC, electrical and plumbing, exits, fire extinguishers, emergency lights and sprinklers, accessibility features, and housekeeping. Each item needs a pass or issue answer, a note, a photo of any problem and a follow-up action.

Who performs a facility inspection?

Usually a facility manager, maintenance supervisor, building engineer or safety coordinator. Specialized items such as fire alarm testing, sprinkler inspections, elevator inspections and boiler inspections are done by licensed contractors on their own schedules; the walk-through checks that those tags and certificates are current.

Is a facility inspection checklist the same as a home inspection?

No. A home inspection is a one-time check of a house for a buyer, usually by a licensed home inspector. A facility inspection checklist is used repeatedly by the people who run a commercial or public building to keep it safe and maintained.

Do this inspection on your phone: AI drafts it, you approve

Inspectial turns the photos, voice notes and GPS from this checklist into a structured, map-ready inspection record. Every finding links to its photo, and nothing is official until you approve it.

An assessor with a clipboard records data beside a gas water heater in a school mechanical room. On the wall to the left, a red circulator pump, valves and a pipe strainer are heavily corroded, and the insulation on overhead pipe fittings is torn. A rusted boiler shell stands at the right edge, and the concrete floor is stained.
Building BLD-01441.6587, -91.5349 · condition assessment pack
  • Heating piping · strainerheavy scale and corrosionAI suggested
  • Heating piping · insulationjacket torn at fittingsAI suggested
  • Heating piping · valvesrust at bonnets and flangesAI suggested